Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13635594
| No.13635594
- Product Categories
- Friendly Links
| Information Name: | 1,200,000 kcal conducting oil furnace oil furnace _ _ Arts boiler |
| Published: | 2015-04-20 |
| Validity: | 0 |
| Specifications: | Limited |
| Quantity: | |
| Price Description: | |
| Detailed Product Description: | Vertical fuel (gas) vertical oil furnace oil furnace gas natural gas as a heat source to oil as a heat carrier oil and gas co-firing oil furnace, heat pump forced circulation, the heat supplied to the vertical thermal equipment fuel (gas) oil furnace [3] energy efficient heating equipment. The device has a compact structure, small size, light weight, simple operation of the device, heating up fast, no environmental pollution, etc., computers active temperature control, can achieve higher operating temperatures at lower operating pressures. Vertical gas oil furnace computer active control, low voltage stable operation, the thermal efficiency of up to 90%. Widely used in petrochemical, oil materials, building materials industry, textile, food, plastics, rubber, pharmaceuticals and other professional oil furnace manufacturer, is a new vision of the heating equipment. How safe use of oil boiler, it is necessary for the operator to have a very high demand, first of all requires the operator to be familiar with the operation of the boiler, oil boiler of the fault can be done ahead of time to prevent, avoid hidden dangers of state boiler operation, the use of the first to open the inlet valve, and then start the injection pump to HTF input to the sump pump and shut off valve, and then enter the system-wide oil furnace oil, open the valve and the inlet valve and the brightest, start injection pump The oil-filled heating system, the exhaust valve opens cold oil replacement after closing, and finally with hot inlet and outlet valves open and the bypass valve closed lower oil furnace prices, oil enters the expansion tank rises above the overflow port back Close Note when sump pumps, and then start the circulation pump run full system exhaust state into the circulation. After gradually warming up to the exclusion of air and exhaust gas circulation system, residual moisture, temperature process to carefully check the entire system for leaks, and make sure there is no leakage, oil flow to maintain adequate circulation during heating, if you want to adjust heat can not be used for reducing the circulation flow approach to the operation, and should be appropriate to open the bypass valve and reduce the oven temperature to adjust for the heat, after the first heat and then reduce the oven temperature to stop circulation pump off. 1,200,000 kcal conducting oil furnace oil furnace _ _ Arts boiler provided by Hebei Arts boiler limited liability company. Hebei Arts boiler limited liability company (www.yi-neng.cn) strong, credible, Cangzhou in Hebei industrial boilers and accessories industry has accumulated a large number of loyal customers. The company better work attitude and constantly improving innovative ideas will lead the arts into the brilliant boiler and you work for a better future! |
Admin>>>
You are the 13251 visitor
Copyright © GuangDong ICP No. 10089450, Hebei Arts boiler limited liability company All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 13251 visitor
Copyright © GuangDong ICP No. 10089450, Hebei Arts boiler limited liability company All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility

